The size of the door standard knowledge

 The door size of the standard really want to say it actually does not have the standard size, but there is a general definition. Although the size of the door has a general definition, but in the decoration, most of the time according to their own love and the actual situation to determine the size of the door.

The door size of the standard really want to say it actually does not have the standard size, but there is a general definition. Although the size of the door has a general definition, but in the decoration, most of the time according to their own love and the actual situation to determine the size of the door.
 
Door height
 
For people access to the door, the height is generally not less than 2m, and then also should not be more than 2.4m high, otherwise there is a sense of empty, door production also need to be strengthened. Such as modeling, ventilation, lighting needs, you can add the waist window, the height from 0.4m, but should not be too high. For vehicles or equipment through the door, according to the specific circumstances of the decision, its height should be higher than the vehicle or equipment 0.3 ~ 0.5m, so as to avoid the vehicle due to bumps or equipment need to move the wheel collision roller frame. As for all types of vehicles through the clearance requirements, to check the corresponding norms.
 
If it is a sports hall, exhibition hall like a large amount of large space, the need to set the size of the door, you can add a large size of the door to the door size, for the door do not need to open, people can pass.
 
Today, the construction of a variety of equipment within the well control a lot of wells, it is not often through the place, so the general box is high and ordinary doors Qi or lower, the bottom also left with the heel line with the high threshold, the net high Do not have to stick to the 2m, 1.5m or so can be.
 
Width:
 
General house door door 0.9 ~ 1m, sub-room door 0.8 ~ 0.9m, kitchen door 0.8m or so, bathroom door 0.7 ~ 0.8m, due to consider the modern furniture into the present more than the upper limit size. Public building door width of a single door 1m, double doors 1.2 ~ 1.8m, then the width of the door to consider the production, double doors or doors of the door wide to 0.6 ~ 1.0m appropriate. The width of the Taiping Gate for safe evacuation shall be set according to the provisions of the calculation and specification (relevant fire protection regulations).
 
Pipes and for maintenance of the door, the width is generally 0.6m. For the motor vehicle or equipment through the door, in addition to its own width, each side also set aside 0.3 ~ 0.5m gap. Incidentally, for the maintenance of the "manhole" its size should not be less than 0.6m × 0.6m.